Blast Chiller Controllers

Dixell XB series Controllers are designed to comply with the rules concerning preparation and chilling of foodstuffs (HACCP)

Buy Best Blast Freezer Controllers

Overview

Overview

Dixell XB series Controllers are designed to comply with the rules concerning preparation and chilling of foodstuffs (HACCP). They have four configurable cycles: pre-set according to the most common food – safety applications: soft chill, hard chill and freezing. They present output for remote display to monitor the core temperature of goods. They have an Internal real time clock and Printer output (XB07PR) for temperature and blast chiller cycles reports. All different phases monitored and shown on the display. Ultra violet sterilization cycle management. They usea a Standard communication protocol ModBUS-RTU for communicating with the system. Hot Key 128 or Prog tool kit connector for a quick and easy programming. 5VA max power absorption. They have a dual display with red LED (8,0mm high) and yellow LED (5,6mm high) and 14 icons.

Specifications

The series XB has been created for fast chilling or freezing goods according to international food safety standards.

There are FOUR types of cycles:

  • The CYCLES:  Cy1, Cy2, Cy3, Cy4 are pre-set according to the most common cycles used in food safety applications; the user can select one of them according to his own requirements and modify it as he wants.
  • Any cycle can be manually terminated before the normal.
  • Any cycle can use the insert probes (up to 3), they measure the internal temperature of the product.
  • During the Cycle there are no defrosts and the fans are always on, a defrost cycle can be done before any freezing cycle.
  • The cycle is divided up to 3 phases completely configurable by the user.
  • Each instrument is provided with an output for remote display XR REP, which shows the temperature of cabinets or goods.
  • The XB570L controller is provided with internal real-time clock and can be connected to the XB07PR printer. This means that a report, which includes all the main features of cycle, can be printed: start and end of the cycle, length of the cycle, logging of the temperature of the cabinet and goods.
  • Design to comply with the rules concerning preparation and chilling of foodstuffs (HACCP)
  • Four configurable cycles: pre-set according to the most common food – safety applications: soft chill, hard chill and freezing
  • Output for remote display to monitor the core temperature of goods
  • Internal real time clock
  • Printer output (XB07PR) for temperature and blast chiller cycles reports
  • All different phases monitored and shown on the display
  • Ultra violet sterilization cycle management
  • Standard communication protocol ModBUS-RTU
  • Hot Key 128 or Prog tool kit connector for a quick and easy programming
  • 5VA max power absorption
  • Dual display with red LED (8,0mm high) and yellow LED (5,6mm high) and 14 icons

Features

  • Compact design
  • Coil windings are insulated to provide shock and vibration protectiion
  • Interchangeable housings
  • Designed to provide weather protection if used with connector (NEMA 2)
Tech Specs

BLAST CHILLER DIGITAL CONTROLLER WITH 4 CONFIGURABLE CYCLES, RTC, PRINTER OUTPUT AND SERIAL OUTPUT

L: 38x185mm

Generals
Keyboard push buttons: 8
First display: n° digits: ± 3 d.p.
Second display: n° digits: ± 4 d.p.
Power supply: 24, 110, 230Vac

Probe inputs
Thermostat: NTC/PTC
Defrost: NTC/PTC
Insert 1: NTC/PTC
Insert 2: NTC/PTC
Insert 3: NTC/PTC

Digital inputs
Alarm: configurable
Door switch: present

Relay outputs
Compressor: 20A
Defrost: 8A
Fans: 8A
Light: 16A
AUX: 8A
Alarm: 16A

Other
Buzzer: present
Real time clock: present
Printer output: XB07PR opt
Remote display output: X-REP opt
Hot Key 128/Prog Tool Kit output: present
Serial output: RS485